Skip to main content

Table 3 Objective quality evaluation results of enhanced signals measured only in speech presence region.

From: Transient noise reduction in speech signal with a modified long-term predictor

Algorithm

Without OM-LSA

With OM-LSA

 

SNR

SSNR

LSD

SNR

SSNR

LSD

Input

- 3.71

- 4.14

17.48

- 1.31

- 1.80

15.57

STP

- 1.57

- 4.21

16.95

- 0.04

- 2.55

15.50

STP and LTP

- 1.42

- 3.96

17.09

0.09

- 1.64

15.25

LTP with Eq. (5)

6.27

2.37

10.74

7.94

4.38

9.55

LTP with Eq. (13)

6.17

2.47

10.44

7.67

5.07

9.26

LTP with Eq. (14)

7.04

3.15

9.90

9.29

5.52

9.07

  1. The SNRs, SSNRs, and LSDs between enhanced signals and desired speech which are measured in speech presence region only.