From: Fault diagnosis of Tennessee Eastman process using signal geometry matching technique
PC i used: | PC1 | PC2 | PC3 | PC4 | PC5 |
---|---|---|---|---|---|
Fault type | |||||
   IDV(0) | 20% | 20% | 5% | 0.0 | 10% |
   IDV(1) | 60% | 100% | 0.0 | 0.0 | 90% |
   IDV(2) | 65% | 100% | 75% | 100% | 15% |
   IDV(3) | 60% | 35% | 50% | 30% | 10% |
   IDV(4) | 15% | 10% | 0.0 | 10% | 55% |
   IDV(5) | 75% | 0.0 | 0.0 | 5% | 60% |
   IDV(6) | 100% | 85% | 100% | 90% | 30% |
   IDV(7) | 95% | 40% | 0.0 | 5% | 90% |