Skip to main content

Table 9 Correct classification rates of TEP stochastic faults using signal templates of five PCs (20 simulations for each fault type)

From: Fault diagnosis of Tennessee Eastman process using signal geometry matching technique

PC i used:

PC1

PC2

PC3

PC4

PC5

Fault type

   IDV(8)

20%

25%

0.0

0.0

0.0

   IDV(9)

40%

75%

5%

5%

45%

   IDV(10)

0.0

0.0

65%

70%

5%

   IDV(11)

60%

25%

30%

35%

45%

   IDV(12)

20%

35%

30%

70%

0.0