Skip to main content

Table 1 SNR of the reconstructed signal versus number of iterations for the second order SDM with λ = 1

From: A sigma–delta analog to digital converter based on iterative algorithm

   

Iteration number

Filter type

OSR

Quantization bits

0

2

4

10

15

20

FIR

16

3

18.15

43.58

55.10

57.06

57.19

57.15

  

5

18.14

43.73

64.18

69.66

69.98

70.02

 

32

3

15.32

42.0

57.96

60.35

60.58

60.67

  

5

15.32

42.16

65.08

77.51

78.33

78.48

 

64

3

21.79

29.63

44.67

67.02

66.46

67.07

  

5

21.98

29.75

44.42

72.89

78.18

77.90

IIR

16

3

15.40

42.76

49.72

51.04

52.48

52.78

  

5

15.40

43.66

61.61

63.07

63.40

64.12

 

32

3

16.12

45.24

57.24

60.16

60.79

61.26

  

5

17.32

46.34

61.67

66.11

67.15

67.50

 

64

3

21.65

30.52

38.83

50.03

66.88

76.96

  

5

21.65

30.52

38.83

50.07

67.32

81.53