Skip to main content

Table 1 Comparison of time delay estimates obtained using CC and the proposed technique based on OC algorithm

From: Sub-sampling-based 2D localization of an impulsive acoustic source in reverberant environments

 

Frequency

True TD

TDE CC

Run time

TDE OC

Run time

 

(kHz)

(ms)

(ms)

CC (s)

(ms)

OC (s)

Case I

16

2.941

2.875

66

2.875

70

 

8

2.941

3.125

17

2.875

7

 

4

2.941

2.250

4.5

3.312

3.5

Case II

16

1.218

1.250

66

1.250

70

 

8

1.218

0.875

17

1.312

7

 

4

1.218

1.000

4.5

1.250

3.5

Case III

16

0.000

0.000

66

0.000

70

 

8

0.000

0.250

17

0.000

7

 

4

0.000

0.750

4.5

0.187

3.5