Skip to main content

Table 1 Parameter values used in the simulations

From: Energy efficiency analysis of relay-assisted cellular networks

Parameter

Value

λ M , λ R

10−5 m−2, 10−4 m−2,

PMU, PRU, PMR

43 dBm, 30 dBm, 33 dBm

R

40 m

α

4

w M , w R

40 MHz, 4 MHz

ΓMR, ΓRU, ΓMR

-10 dB, -10 dB, -10 dB

σ 2

−60 dBm

β M , β R

5.32, 4.8

PM0, PR0

118.7 W, 7.5 W