Table 2 Accuracy of estimates corresponding to three criteria

From: Improvements for electromechanical oscillation mode estimation via subspace identification methods

Mode

Reference value

AIC BIC

SVC

Uncertainty

RMSE

Uncertainty

RMSE

Local mode 1

Freq (Hz)

1.056

0.962 ± 0.021

0.094

0.992 ± 0.020

0.065

DR (%)

19.87

18.86 ± 3.88

2.18

18.87 ± 3.68

2.13

Local mode 2

Freq (Hz)

1.071

0.964 ± 0.021

0.108

0.999 ± 0.020

0.073

DR (%)

19.57

18.13 ± 4.16

2.41

18.39 ± 4.12

2.26

Inter-area

Freq (Hz)

0.565

0.589 ± 0.018

0.025

0.567 ± 0.018

0.009

DR (%)

10.28

11.51 ± 3.04

2.16

11.07 ± 3.02

1.94