Skip to main content

Table 5 Comparison of R-peak detection with other algorithms

From: A novel method for the detection of R-peaks in ECG based on K-Nearest Neighbors and Particle Swarm Optimization

Algorithm Year Se(%) +P% DER(%) Beats
Ref. [ 16 ] 1997 99.42 99.35 1.22 14,481
Ref. [ 36 ] 2006 99.55 99.49 0.96 102,654
Ref. [ 32 ] 2007 97.94 99.13 2.92 60,431
Ref. [ 11 ] 2008 99.57 99.59 0.84 109,903
Ref. [ 25 ] 2012 99.60 99.50 0.61 19,098
Ref. [ 42 ] 2015 99.43 99.67 0.88 109,494
Our method 2017 99.69 99.72 0.58 108,184