Skip to main content

Table 5 Classification accuracy with selected segment of HRV for training and testing

From: Intelligent prediction of sudden cardiac death based on multi-domain feature fusion of heart rate variability signals

Time

Acc

SCD10

92.11%

SCD30

92.11%

SCD40

92.11%

SCD50

86.84%

SCD60

84.21%

SCD70

92.11%

Mean ± standared deviation

89.92% ± 3.5%