Table 3 Comparison of calculation time between FFT harmonic analysis method and digital quadrature detection method

From: A low computation detection method of signal nonlinear distortion based on digital quadrature detection principle

Calculate points

Calculation time of FFT (us)

5th-order THD calculation time of DQD(us)

5th-order THD calculation time ratio (%)

15th-order THD calculation time of DQD(us)

15th-order THD calculation time reduction ratio (%)

128

1977.6

530.72

73.16

1602.56

18.96

256

3971.1

885.94

77.69

2664.26

32.91

512

8088

1605.02

80.16

4780.09

40.90

1024

16,226

3055.56

81.17

9039.5

44.29