Skip to main content

Table 5 Test results of 5th-order total harmonic distortion of customized signal (256 points)

From: A low computation detection method of signal nonlinear distortion based on digital quadrature detection principle

Fundamental frequency (Hz)

Peak to peak (mVpp)

Custom distortion (%)

FFT harmonic analysis method (%)

Error (%)

Digital quadrature detection method (%)

Error (%)

Method error comparison (%)

150

2688

7.14

7.11

0.46

7.17

0.34

− 0.12

350

2432

30.28

30.19

0.28

30.30

0.07

− 0.21

750

2377

15.38

15.34

0.30

15.43

0.32

0.02

1150

1662

35.76

35.61

0.44

35.93

0.46

0.02

1550

2688

10.97

11.02

0.45

11.03

0.52

0.07

1950

2759

15.43

15.50

0.42

15.48

0.33

− 0.09