Skip to main content

Table 6 Test results of 10th-order total harmonic distortion of customized signal (256 points)

From: A low computation detection method of signal nonlinear distortion based on digital quadrature detection principle

Fundamental frequency (Hz)

Peak to peak (mVpp)

Custom distortion (%)

FFT harmonic analysis method (%)

Error (%)

Digital quadrature detection method (%)

Error (%)

Method error comparison (%)

150

2688

10.10

10.09

0.09

10.11

0.05

− 0.04

350

2432

35.75

36.02

0.76

36.06

0.87

0.11

750

2377

23.33

23.03

1.29

23.56

0.96

− 0.33

1150

1662

38.26

37.73

1.39

38.85

1.54

0.15

1550

2688

14.03

13.84

1.36

14.20

1.16

− 0.20

1950

2759

17.46

17.72

1.47

17.71

1.43

− 0.04