Skip to main content

Table 7 Test results of 15th-order total harmonic distortion of customized signal

From: A low computation detection method of signal nonlinear distortion based on digital quadrature detection principle

Fundamental frequency (Hz)

Peak to peak (mVpp)

Custom distortion (%)

FFT harmonic analysis method (%)

Error (%)

Digital quadrature detection method (%)

Error (%)

Method error comparison (%)

150

2688

22.57

23.20

2.81

23.34

3.41

0.60

350

2432

58.68

60.62

3.32

60.65

3.36

0.04

750

2377

38.83

39.72

2.29

39.97

2.92

0.63

1150

1662

77.40

80.57

4.10

80.84

4.45

0.35

1550

2688

28.33

29.53

4.22

29.62

4.56

0.34

1950

2759

32.11

33.63

4.73

33.41

4.05

− 0.68