Skip to main content

Table 8 Comparison for sampling and analysis

From: Estimation of LFM signal parameters using RD compressed sampling and the DFRFT dictionary

Signal

Sampling method

Sampling frequency (MHz)

Sampling points

Compression ratio

Signal 3

Nyquist

150

3061

–

 

RD

8

163

18.75:1

Signal 4

Nyquist

150

2562

–

 

RD

10

171

15: 1

  1. Bold values indicate the best performance among the different methods