Skip to main content

Table 2 Denoising effect of thresholding algorithms on Heavysine signals

From: An improved wavelet threshold denoising approach for surface electromyography signal

Denoising function

Quantitative metrics

SNR

MSE

Hard threshold(sqtwolog)

24.1347

0.0368

Soft threshold(sqtwolog)

23.9735

0.0381

Hard threshold(rigrsure)

18.3669

0.1368

Soft threshold(rigrsure)

23.2683

0.0449

Hard threshold(heursure)

23.0693

0.047

Soft threshold(heursure)

24.5043

0.0338

Hard threshold(minimaxi)

19.3135

0.1115

Soft threshold(minimaxi)

24.4135

0.0344

Garrote threshold

24.6503

0.0326

Improved threshold

25.4245

0.0273